  Datasheet File OCR Text:
 MAP110 SERIES
Power-One's MAP110 series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure world-wide acceptance. All units bear the CE Mark. FEATURES * New 3.3V and 5V Output Models * Universal Input 85-264 VAC * Industry Standard Footprint: 7.00" x 4.30" x 1.97" (177.8mm x 109.2mm x 50.0mm) * Input Transient & ESD Compliance to EN61000-4-2/-3/-4 * Greater than 134,000 Hours MTBF * Remote Sense and Over-Voltage Protection on Single Output Units and Main Output of Multiple Output Units * Options Include Over-Temperature Protection, Power Fail Signal, Chassis & Cover SINGLE OUTPUT MODEL SELECTION CHART
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT FORCED AIR OUTPUT CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 1) INITIAL SETTING ACCURACY
Wide dynamic output current and fixed frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user specific output voltage requirements.
MAP110-1005 5V MAP110-1012 12V/15V MAP110-1024 24V/28V
4.95V to 5.50V 11.25V to 15.75V 22.8V to 29.2V
16A 7.5/6A (Note 2) 3.8/3.2A (Note 2)
22A 10/8A (Note 2) 5.0/4.3A (Note 2)
0.2% 0.1% 0.1%
1% 0.5% 0.5%
1% 1% 1%
5.09V to 5.11V 11.97V to 12.02V 23.95V to 24.05V
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
MULTIPLE OUTPUT MODEL SELECTION CHART - 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT (NOTE 1) FORCED AIR CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY
MAP110-4000
MAP110-4001
MAP110-4002
MAP110-4003
MAP110-4004
+5V +12V -12V -5V +5V +24V -12V +12V +5V +12V -12V +12V +5V +15V -15V -5V +5V +24V -15V +15V
4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed
12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/7.3A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK
12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/7.3A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 3A/4.5A PK 1A/1.5A PK 1A/1.5A PK
0.2% 0.2% 0.2% 0.2% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.2% 0.2% 0.1% 0.1% 0.1%
0.5% 1% 1% 1.5% 0.5% 1% 1% 1% 0.5% 1% 1% 1% 0.5% 1% 1% 1.5% 0.5% 1% 1% 1%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V -4.75V to -5.25V 5.09V to 5.11V 23.94V to 24.06V -11.4V to -12.6V 11.4V to 12.6V 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V 11.4V to 12.6V 5.09V to 5.11V 14.96V to 15.04V -14.3V to -15.7V -4.75V to -5.25V 5.09V to 5.11V 23.94V to 24.06V -14.3V to -15.7V 14.3V to 15.7V
Rev. 03/2001
1
MAP110 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) - 80W CONVECTION COOLED, 110W FORCED AIR COOLED (200 LFM)
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED CURRENT (NOTE 1) FORCED AIR CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY
MAP110-4010
MAP110-4011
MAP110-4015
MAP110-4200
New
MAP110-4300 (Note 3)
New
MAP110-4305 (Note 3)
NOTES:
+5V +12V -5V -12V +5V +12V -12V +24V +5V +12V -15V +15V +12V +24V -12V +5V +3.3V +5V -12V +12V +3.3V +5V -5V +12V
4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 4.75V to 5.25V Fixed Fixed Fixed 11.55V to 12.45V Fixed Fixed Fixed 3.2V to 3.4V Fixed Fixed Fixed 3.2V to 3.4V Fixed Fixed Fixed
12A/20A PK 5A/9A PK 1A/1.5A PK 3A/4A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 5A/9A PK 4A/4.5A PK 1A/1.5A PK 2A/2.5A PK 12A/20A PK 5A/12A PK 1A/1.5A PK 1A/1.5A PK 12A/15A PK 5A/12A PK 1A/1.5A PK 1A/1.5A PK
12A/20A PK 5A/9A PK 1A/1.5A PK 3A/4A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 12A/20A PK 5A/9A PK 1A/1.5A PK 1A/1.5A PK 5A/9A PK 4A/4.5A PK 1A/1.5A PK 2A/2.5A PK 15A/20A PK 8A/12A PK 1A/1.5A PK 1A/1.5A PK 15A/20A PK 8A/12A PK 1A/1.5A PK 1A/1.5A PK
0.2% 0.1% 0.2% 0.3% 0.2% 0.1% 0.1% 0.1% 0.2% 0.1% 0.1% 0.1% 0.2% 0.2% 0.2% 0.2% 0.3% 0.2% 0.1% 0.1% 0.3% 0.2% 0.1% 0.1%
0.5% 2% 1.5% 8% 0.5% 1% 1% 1% 0.5% 1% 1% 1% 0.5% 1% 1% 1.5% 0.7% 1% 1% 1% 0.7% 1% 1% 1%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 0.5% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
5.09V to 5.11V 11.97V to 12.03V -4.75V to -5.25V -11.5V to -12.5V 5.09V to 5.11V 11.97V to 12.03V -11.4V to -12.6V 23.2V to 24.8V 5.09V to 5.11V 11.97V to 12.03V -14.4V to -15.6V 14.4V to 15.6V 11.96V to 12.03V 23.94V to 24.06V -11.4V to -12.6V 4.75V to 5.25V 3.29V to 3.31V 4.98V to 5.02V -11.4V to -12.6V 11.4V to 12.6V 3.29V to 3.31V 4.98V to 5.02V -4.75V to -5.25V 11.4V to 12.6V
1) Peak loads up to 110 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 Watts. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3) Sum of the output currents of V1 + V2 may not exceed 15A continuous, 22A peak.
MAXIMUM OUTPUT RATING:
MODEL/OUTPUT OPTION MULTIPLE OUTPUT BOARD ONLY SINGLE OUTPUT BOARD ONLY MULTIPLE OUTPUT `L'-BRACKET SINGLE OUTPUT `L'-BRACKET MULTIPLE OUTPUT `C'-COVER SINGLE OUTPUT C'-COVER
CONVECTION CONTINUOUS/PEAK FORCED AIR 200 LFM
80W/110W 110W
90W/120W 120W
80W/110W 110W
90W/120W 120W
60W/110W 110W
65W/120W 120W
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Input Frequency Brown Out Protection Hold-up Time Input Current Input Protection Inrush Surge Current Operating Frequency
Continuous input range. AC input. Lowest AC input voltage that regulation is maintained with full rated loads. Nominal AC input voltage (110 VAC) 50% load: Full rated load: 85 VAC (110W load). 110VAC (110W load). Non-user serviceable internally located AC input line fuse. Internally limited by thermistor. Vin = 264 VAC (one cycle). 25C. Switching frequency of main transformer, (fixed frequency).
85 47 85 40 20
264 63
VAC Hz VAC mS ARMS
3.5 2.8 41 20 25
APK kHz
2
MAP110 SERIES
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Minimum Loads Ripple and Noise Output Power Overshoot / Undershoot Regulation
Transient Response Turn-on Delay Turn-on Rise Time
Full load, 230 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, V1 + V2 (Note 1). Full Load, 20 MHz Bandwidth. Multiple output units with convection cooling. Multiple output units with 200 LFM forced air cooling. Output voltage overshoot/undershoot at turn-on. Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
65 0 1 5 5
75
% Amps Amps See Model Selection Chart. 80 Watts 110 Watts 0 V
80
See Model Selection Chart.
500 1 20
S Sec mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection
Provided on single output models and the main output of multiple output models.
MAP110-1005 MAP110-1012 MAP110-1024 MAP110-4200 MAP110-4300 All other models.
6.10 17.3 32.2 13.8 3.7 5.75 150
Overload Protection Remote Sense Input Power Fail Warning Overtemperature Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Voltage drop compensated for at the load. Option, TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. Active low. Option, system shutdown due to excessive internal temperature.
7.20 20.2 37.8 16.2 4.35 6.75 200 250
V
% mV mS
3
5
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference, Conducted Input Transient Protection Insulation Resistance Leakage Current
UL1950. CSA 22.2 No. 234/950. EN60950 (TUV). Input to Output. FCC CFR title 47 part 15 sub-part B - conducted & radiated. EN55022 / CISPR 22 conducted. EN55022 / CISPR 22 radiated (Note 2). EN61000-4-5 level 3. Input to output. Per EN60950, 264 VAC.
Approved. 2600 B B A 2 10 750 VDC Class kV M A
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary. 2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
3
MAP110 SERIES
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity
Operating. Non-operating. Derate linearly above 50C by 2.5% per C to a maximum temperature of 70C. 0C to 70C. Non-condensing.
At 100% load: At 50% load:
0 0 -55 0.03
10k 50k 50 70 85 0.05 95
ASL Ft. ASL Ft. C C C %/C %RH
OPTIONS
DESCRIPTION NOTES DIMENSIONS
L-Bracket Cover Power Fail Signal Thermal Shutdown
Add `L' suffix to model number. Add `C' suffix to model number. Includes L-Bracket. Add `P' suffix to model number. Provides >5 mS typical warning time before main output drops 5%. Warning time increases at reduced load levels. Add `T' suffix to model number. Initiates shut-down in the event of an overtemperature condition. Automatic recovery.
7.15" x 4.50" x 2.40" (182.0mm x 115.0mm x 61.0mm) 7.20" x 4.50" x 2.40" (183.0mm x 115.0mm x 61.0mm) N/A N/A
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
4
MAP110 SERIES
OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm) OVERALL WEIGHT: 1.3 LBS (0.59 kg)
NOTE 1
Contact factory for dimensions for L-bracket and cover.
5


▲Up To Search▲   

 
Price & Availability of MAP110-4004

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X